High Power Femtosecond Yb CPA Laser

expired opportunity(Expired)
From: MerX(Federal)
43981-2A-RFP

Basic Details

started - 27 Mar, 2024 (1 month ago)

Start Date

27 Mar, 2024 (1 month ago)
due - 24 Apr, 2024 (7 days ago)

Due Date

24 Apr, 2024 (7 days ago)
Bid Notification

Type

Bid Notification
43981-2A-RFP

Identifier

43981-2A-RFP
University of Ottawa

Customer / Agency

University of Ottawa
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

High Power Femtosecond Yb CPA Laser Project Description :The Unversity of Ottawa is pleased to invite qualified proponents to submit a proposal for a laser that will be used for driving two optical parametric amplifiers (OPA). The OPA outputs serve as seed pulses for a high-power mid-infared laser system.The laser needs to produce two outputs at the same time. Each channel is to deliver no less than 2 mJ, pulses shorter than 250 fs, at 5 kHz. The carrier-envelope phase of the pulses from at least one of the channels must be stabliized. Mandatory Requirements: 1. Yb CPA Laser 1.1 Pulse Duration full width at half maximum (FWHM) must be: 100 fs ≤ t ≤ 250 fs. 1.2 Central Wavelength λc must = 1030 ± 50nm. 1.3 Pulse Energy (Single Shot to 5 kHz) must be either two channels where E ≥ 2 mJ for each channel, or one channel where E ≥ 4 mJ 1.4 The laser must be capable of achieving two outputs simultaneously. 1.5 Repetition rate must be: 1 Hz ≤ frep ≤ 50 kHz. 1.6 Power stability must be < 0.5 %
Root Mean Square (RMS) 1.7 Output beam quality must be M2 <1.3 1.8 Polarization must be Linear 1.9 Power must be either 120 VAC or 208 VAC, single phase, <2 kHz 1.10 Pulse selection: any base repetition rate division (the repetition rate can be the maximum value divided by any power of 2; such as 2,4,8, etc.) 1.11 The carrier-envelope phase of the pulses from a minimum of one channel must be stabilized. Said stabilization of the slow-loop carrier envelope phase must be < 350 mrad RMS. 1.12 Oscillator carrier envelope phase standard deviation must be < 150 mrad 1.13 Must include either an air-to-water cooled chiller suitable for instrument. 2. Other Requirements 2.1 Installation and training must be included. 2.2 The instrument must operate for a minimum of 8 consecutive hours; 5 days per week. 2.3 Must include one (1) year warranty on parts and labor. 2.4 Must be capable of providing up to a total of 5 years of extended warranty. 2.5 All electrical components must have CSA (Canadian Standards Association) certification or accepted equivalent as per Electrical Safety Authority Recognized Certification Mark at the following link: https://esasafe.com/electrical-products/recognized-certification-marks/ Otherwise, all electrical components must be able to undergo the applicable electrical inspection, and/or, certification, without voiding the system warranty. Contact Information :-Owen Bouley 613-562-5800 ext. 3966 obouley@uottawa.ca

MERX 6 Antares Dr, Phase II unit 103 Ottawa, ON K2E 8A9Location

Address: MERX 6 Antares Dr, Phase II unit 103 Ottawa, ON K2E 8A9

Country : CanadaState : Ontario

You may also like

C000475 - ConvergeOne, Inc. - Amendment 2

Due: 03 May, 2024 (Tomorrow)Agency: Information Technology Services, NYS Office of

High Power Curve Tracker

Due: 03 May, 2024 (Tomorrow)Agency: COMMERCE, DEPARTMENT OF

IMPROVEMENTS TO THE GPM RADIOMETER ALGORITHM

Due: 30 Sep, 2024 (in 5 months)Agency: NATIONAL AERONAUTICS AND SPACE ADMINISTRATION

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.