Piping Services Provider

expired opportunity(Expired)
From: University of Iowa(Higher Education)
17263

Basic Details

started - 01 Feb, 2019 (about 5 years ago)

Start Date

01 Feb, 2019 (about 5 years ago)
due - 01 Mar, 2019 (about 5 years ago)

Due Date

01 Mar, 2019 (about 5 years ago)
Bid Notification

Type

Bid Notification
17263

Identifier

17263
University of Iowa

Customer / Agency

University of Iowa

Attachments (4)

unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

Login Bid Opportunity Detail Return To ListingSupplier Registration Bid InformationTypeRequest for Proposal - SealedStatusIssuedNumber17263 Addendum 3 (Piping Services Provider)Issue Date & Time2/1/2019 04:10:55 PM (CT)Close Date & Time3/1/2019 03:00:00 PM (CT)Time Left19 hours 59 minutes 33 seconds NotesPlease be aware that this is an extensive bid. All Suppliers are cautioned to allow ample time for the submittal of RFP responses well before the due date time requirement. Bids must be submitted via the eBid system. Addendum 1 issued to change the deadline for questions from Sunday, February 10 to Monday, February 11. Questions will be reviewed after the deadline and answers will be posted as soon as possible. Addendum 2 issued to upload 'Anchor Drawings' attachment for use with pricing scenario #2. Contact Information NameGreg SnipesAddress202 PCO Iowa City, IA 52242-2500Phone319 (335) 0403 Fax319 (335) 2443 Emailgreg-snipes@uiowa.edu
Bid Documents Document nameFormat type Bid Document [Old Format] Acrobat / PDF Bid Invitation Acrobat / PDF Bid Attachments File NameDescriptionFile Size UI Standard Terms and Conditions_Final_11-26-18.pdf University of Iowa Terms and Conditions260 KB Anchor Drawings.pdf Anchor Drawings for Scenario #21 KB Bid Questions Question Scenario #2: Please provide specific details regarding type of anchor, what is the failure, size, and anything else that might be relevant. AnswerAssume failure is a bent and stressed anchor that was damaged by water hammer. Please refer to the 'Anchor Drawings' on the Attachments tab for drawings from which a proposal can be developed.Submitted2/3/2019 11:00:25 PM (CT) Question Scenario #1: What size is the pipe? Carbon steel or stainless? Sch40 or Sch80 pipe? Location (ground level, tunnel, 40' in the air, etc.)? Is Xray required? Confined space? Weld specification/rRequirements? AnswerAssume 12-inch diameter, Schedule 40 carbon steel, in a dry tunnel, chest-high. Xray is not required on a repair. Weld requirements: TIG root pass with stick filler and cover.Submitted2/2/2019 11:58:48 AM (CT)

202 PCO Iowa City, IA 52242-2500Location

Address: 202 PCO Iowa City, IA 52242-2500

Country : United StatesState : Iowa

Classification

Department of Transportation